2.12.2 Data Adjustment Settings of Injection Molding Machine

 
Path: F10 next –> F3 adjustment –> F3 DA1
 
Data Adjustment Settings of Injection Molding Machine

DA2,DA3,DA4 and DA1 picture and function are similar

 
Output force: DA correction during the test output, the corresponding channel’s output continued to the timing, when the timing has reach the limit , the output will automatically be cut off.
 
Test:During testing, insert the pressure and flowing preset value as required.
 
Output:The corresponding value of the host computer
 
Reference value:Preset value of the DA curve by the system
 
Actual value:Value after adjustment according to the actual demand of the DA curve.
 
Example of the operation:(the first group of proportional valve):
 
Select the node point from 0 to 140 for the testing such as 60. Then, enter 60 into the testing point, the system will immediately respond to the feedback output value of 60. Then, by observing the machine pressure gauge of their own systems or external pressure test tools, the real pressure is assumed to be 58. In the corresponding node, change 60 to 58! If the actual pressure is 58.5, while at the corresponding node, 60 will be changed to 58 or 59, then adjust the figures for the corresponding binary output value to achieve the adjustment.
 
If you need other options of adjustment please contact Techmation for further requirements!

 
 