Core parameters details on injection molding machines. Including Core – Pressure Ramp, Core – Flow Ramp, Core – Movement time, etc.
No. | Core – Pressure Ramp 1 | ||
---|---|---|---|
Core A In | Core A In Pressure Ramp – The increase slope of core A in pressure buildup time. | ||
Core B In | Core B In Pressure Ramp – The increase slope of core B in pressure buildup time. | ||
Core A Out | Core B In Pressure Ramp – The increase slope of core B in pressure buildup time. | ||
Core B Out | Core B Out Pressure Ramp – The increase slope of core B Out pressure buildup time. | ||
No. | Core – Flow Ramp 1 | ||
---|---|---|---|
Core A In | Core A In Pressure Ramp – The increase slope of core A in speed buildup time. | ||
Core B In | Core B In Pressure Ramp – The increase slope of core B in speed buildup time. | ||
Core A Out | Core A Out Pressure Ramp – The increase slope of core A Out speed buildup time. | ||
Core B Out | Core B Out Pressure Ramp – The increase slope of core B Out speed buildup time. | ||
No. | Core – Pressure Ramp 2 | ||
---|---|---|---|
Core C In | Core C In Pressure Ramp – The increase slope of Core C in pressure buildup time. | ||
Core C Out | Core C Out Pressure Ramp – The increase slope of Core C Out pressure buildup time. | ||
No. | Core – Flow Ramp 2 | ||
---|---|---|---|
Core C In | Core C In Pressure Ramp – The increase slope of Core C in speed buildup time. | ||
Core C Out | Core C Out Pressure Ramp – The increase slope of Core C Out speed buildup time. | ||
No. | Core – Movement time 1 | ||
---|---|---|---|
Core A In | Core forward time delayed – Core forward time is slower then the output time. | ||
Core B In | Core backward time delayed – Core backward time is slower then the output time. | ||
Core A Out | Core forward starting scale valve delay open – The pressure and speed after the core in movement start is slower then the output time. | ||
Core B Out | Core forward end direction valve delay stop – Stop the pressure flow of the core in movement first then delay the stop time if the direction valve. | ||
Core E Out | Core backward starting scale valve delay open – The pressure and flow after the core in movement start is slower then the output time. | ||
Core F Out | Core backward end direction valve delay stop – Stop the pressure flow of the core out movement first then delay the stop time if the direction valve | ||
No. | Core – Movement time 2 | ||
---|---|---|---|
Core A In | Core in start ratio valve open delay – The pressure flow of the core in movement starting delay the output time. | ||
Core B In | Core in ends direction valve stop delay – The pressure flow of the core in movement end , after the delay of time stop the direction valve. | ||
Core A Out | Core out start ratio valve open delay – The pressure flow of the core out movement starting delay the output time. | ||
Core B Out | Core out ends direction valve stop delay – The pressure flow of the core out movement end, after the delay of the time stop the direction valve. | ||