4.5 Core parameters on injection molding machines

Core parameters details on injection molding machines. Including Core – Pressure Ramp, Core – Flow Ramp, Core – Movement time, etc.

Core parameters on injection molding machines

 
 

No. Core – Pressure Ramp 1
Core A In Core A In Pressure Ramp – The increase slope of core A in pressure buildup time.
Core B In Core B In Pressure Ramp – The increase slope of core B in pressure buildup time.
Core A Out Core B In Pressure Ramp – The increase slope of core B in pressure buildup time.
Core B Out Core B Out Pressure Ramp – The increase slope of core B Out pressure buildup time.

 
 

No. Core – Flow Ramp 1
Core A In Core A In Pressure Ramp – The increase slope of core A in speed buildup time.
Core B In Core B In Pressure Ramp – The increase slope of core B in speed buildup time.
Core A Out Core A Out Pressure Ramp – The increase slope of core A Out speed buildup time.
Core B Out Core B Out Pressure Ramp – The increase slope of core B Out speed buildup time.

 
 

No. Core – Pressure Ramp 2
Core C In Core C In Pressure Ramp – The increase slope of Core C in pressure buildup time.
Core C Out Core C Out Pressure Ramp – The increase slope of Core C Out pressure buildup time.

 
 

No. Core – Flow Ramp 2
Core C In Core C In Pressure Ramp – The increase slope of Core C in speed buildup time.
Core C Out Core C Out Pressure Ramp – The increase slope of Core C Out speed buildup time.

 
 

No. Core – Movement time 1
Core A In Core forward time delayed – Core forward time is slower then the output time.
Core B In Core backward time delayed – Core backward time is slower then the output time.
Core A Out Core forward starting scale valve delay open – The pressure and speed after the core in movement start is slower then the output time.
Core B Out Core forward end direction valve delay stop – Stop the pressure flow of the core in movement first then delay the stop time if the direction valve.
Core E Out Core backward starting scale valve delay open – The pressure and flow after the core in movement start is slower then the output time.
Core F Out Core backward end direction valve delay stop – Stop the pressure flow of the core out movement first then delay the stop time if the direction valve

 
 

No. Core – Movement time 2
Core A In Core in start ratio valve open delay – The pressure flow of the core in movement starting delay the output time.
Core B In Core in ends direction valve stop delay – The pressure flow of the core in movement end , after the delay of time stop the direction valve.
Core A Out Core out start ratio valve open delay – The pressure flow of the core out movement starting delay the output time.
Core B Out Core out ends direction valve stop delay – The pressure flow of the core out movement end, after the delay of the time stop the direction valve.

 
 