In this section, we will talk about how to get to charge function settings screen. And what are the meanings of Suck back control mode, Charge back pressure valve,Suck back control before charging,Back pressure proportion and Charging control once again.
Charge function settings process path: screen –> F4 charge –> F4 function
Charge function settings screen of Powerjet plastic injection machine
Suck back control mode: When the selection of the suck back time control is selected, the suck back position settings column unit will change to time which means suck back movement timing settings are available.
Charge back pressure valve:You can either choose output or not output during the charge back pressure valve.
Suck back control before charging:Selection of time and position control is available during the suck back movement before charging.
Back pressure proportion: If the machine consists of this function, you can either choose use or not use.
Charging control once again: Selection of position and time control is available during charging before injection.